7Managing the deviceIf an I2C failure has not occurred, there will be no I2C messages in the static log, dynamic log, orSNMP log server. The following example shows output from the show logging comm<strong>and</strong> when thereis no I2C failure.<strong>Brocade</strong># show loggingSyslog logging: enabled (0 messages dropped, 0 flushes, 1 overruns)Buffer logging: level ACDMEINW, 50 messages loggedlevel code: A=alert C=critical D=debugging M=emergency E=errorI=informational N=notification W=warningStatic Log Buffer:Apr 16 18:21:25:A:System: Power Supply 2 , middle, Not Installed (FAILED)Apr 16 18:21:25:A:System: Power Supply 3 , top, Not Installed (FAILED)Dynamic Log Buffer (50 lines):Mar 28 12:36:47:A:System: Set fan speed to MED (75%)Mar 25 21:40:47:A:System: Set fan speed to MED-HI (90%)Mar 25 16:30:47:A:System: Set fan speed to MED (75%)Mar 23 23:12:07:A:System: Set fan speed to MED-HI (90%)If the system detects a major I2C failure, the system prevents the management module fromaccessing devices through the l2C serial bus. The output from the show chassis comm<strong>and</strong> <strong>and</strong> theshow temperature comm<strong>and</strong> reflect this action, as shown in these examples.<strong>Brocade</strong># show chassis*** Note: ****** Global I2C Error Indicator is set (severity: Major). ****** All I2C access are skipped. ****** <strong>Brocade</strong> <strong>MLX</strong>-4 device ***---POWERS ---Slot Power-On Priority <strong>and</strong> Power Usage:Slot2 pri=1 module type=NI-<strong>MLX</strong>-1Gx20-GC 20-port 10/100/1000 Copper Module power usage=146WSlot4 pri=1 module type=NI-X-OC48x4 4-port OC48/12 STM16/STM4 Module power usage=132W---FANS ------TEMPERATURE READINGS ---LP2 Sensor1: 34.500CLP2 Sensor2: 44.125CThe following output is from the show temperature comm<strong>and</strong> with the GIEI set to major severity.<strong>Brocade</strong># show temperature*** Note: ****** Global I2C Error Indicator is set (severity: Major). ****** All I2C access are skipped. ***SLOT #: CARD TYPE: SENSOR # TEMPERATURE (C):2 LP 1 34.0C2 LP 2 44.250C4 LP 1 36.0C4 LP 2 45 750CDisplaying device status <strong>and</strong> temperature readingsYou can display the following information about the router:• Power-on priority of the device slots• Status of the fans• Temperature readings of the management, switch fabric, interface, <strong>and</strong> fan control modules<strong>and</strong> the interval at which the system reads the temperature of these modules• MAC address of the device324 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!