13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3Installing a <strong>Brocade</strong> <strong>MLX</strong>-32 routerYou can install one 32-slot router in a st<strong>and</strong>ard 2-post or 4-post 19-inch rack or open framecabinet, in either a front-mount position or a mid-mount position. You must provide eight st<strong>and</strong>ard#12-24 pan-head screws to secure the router in the rack. You will need a #2 Phillips screwdriver toperform this task.NOTEBecause of the weight of a fully-populated 32-slot chassis, it is not recommended that you installyour 32-slot router in a 2-post rack or open cabinet. The preferred installation is in a 4-post rack oropen cabinet. Refer to “Installing your 32-slot router in a 4-post rack or open cabinet” on page 205for installation instructionsNOTEIf you are installing your device in a 2-post rack or open cabinet, you will need to purchase the OpenFrame EIA 310-D Rack Mount Kit.Installation requirementsAllow 1 to 2 hours to complete this procedure. Your installation site must meet the followingrequirements to ensure correct installation <strong>and</strong> operation:• Provide 35 U of space in a 19 inch rack or open cabinet.• Verify that the additional weight of the router does not exceed the weight limits for the rack orthe floor.• Ensure that an electrical branch circuit with the following characteristics is available:- Required voltage <strong>and</strong> frequency as indicated in the hardware reference manual.- Protection by a circuit breaker in accordance with local electrical codes.- Supply circuit, line fusing, <strong>and</strong> wire size that conform to the electrical rating on the routernameplate.- Grounded outlet compatible with the power cord <strong>and</strong> installed by a licensed electrician.• Ensure that all equipment installed in the rack is grounded through a reliable branch circuitconnection. Do not rely on a secondary connection to a branch circuit, such as a power strip.• Ensure that the rack is mechanically secured to support the router model.Ensure that theairflow available at the inlet air vents does not exceed 40 o Celsius (104 o Fahrenheit).• Only one 32-slot device can be mounted in each rack or cabinet, positioned as close to thebottom of the rack as possible.• The empty device weighs approximately 362 lbs. You will need a mechanical device (such as amaterial lift), <strong>and</strong> at least two people to guide the device into place.• Before you install the device, make sure that the rack is in a permanent location <strong>and</strong> issecured to the floor or wall of the building. The installation site must allow adequate clearancefor airflow, installation, <strong>and</strong> maintenance.Tool requirements <strong>and</strong> parts listYou will need the following tools to install a 32-slot device in a rack or open cabinet.• A forklift or pallet jack to move the router while it is on the pallet (500 lbs. minimum).• Insertion-extraction tool for use with RJ45 <strong>and</strong> fiber-optic connectors198 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!