13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

9<strong>Hardware</strong> specifications for <strong>Brocade</strong> <strong>MLX</strong> routers<strong>Hardware</strong> specifications for <strong>Brocade</strong> <strong>MLX</strong> routersThe following sections describe hardware specifications for <strong>Brocade</strong> <strong>MLX</strong> routers.Power specificationsThe following power supply frequency requirements apply to <strong>Brocade</strong> <strong>MLX</strong> 4-slot, 8-slot, <strong>and</strong> 16-slotrouters:• AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply• AC Operating Voltage Range: 90 - 264V, 50/60 Hz• Inrush current: 40A peak maximum at 25 degrees C (77 degrees F)• DC Input Rating: -48V, 30.0 A maximum per power supply• DC Operating Range: -40 to -60V• Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)The following power supply frequency requirements apply to the <strong>Brocade</strong> <strong>MLX</strong>-32 routers:• AC Input Rating: 200 -240V, 50/60 Hz, 16.0 A maximum per power supply• AC Operating Voltage Range: 180 to 264V• Inrush current: 30A peak maximum at 25 degrees C (77 degrees F)• DC Input Rating: -48V, 60.0 A maximum per power supply• DC Operating Range: -40 to -60V• Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)Table 57 lists power consumption information for <strong>Brocade</strong> <strong>MLX</strong> routers with all base componentsinstalled, <strong>and</strong> with only the specified interface modules installed.TABLE 57<strong>Brocade</strong> <strong>MLX</strong> router power consumption valuesModel @100 VAC @200 VAC @-48VDCAmps Watts BTU/hr Amps Watts BTU/hr Amps Watts BTU/hr<strong>MLX</strong> routers with 8x10G interface modules only<strong>MLX</strong>-4 14 1389 4740 7 1389 4740 29 1389 4740<strong>MLX</strong>-8 28 2760 9419 14 2760 9419 57 2760 9419<strong>MLX</strong>-16 56 5591 19081 28 5591 19081 116 5591 19081<strong>MLX</strong>-32 N/A N/A N/A 57 11391 38876 237 11391 38876<strong>MLX</strong> routers with48-T-A interface modules only<strong>MLX</strong>-4 15 1445 4967 7 1455 4967 30 1435 4967<strong>MLX</strong>-8 29 2893 9873 14 2893 9873 60 2893 9873<strong>MLX</strong>-16 59 5857 19991 29 5857 19991 122 5857 19991<strong>MLX</strong>-32 N/A N/A N/A 60 11924 40696 248 11924 40696<strong>MLX</strong> routers with legacy <strong>MLX</strong> interface modules only<strong>MLX</strong>-4 13 1313 4480 7 1313 4480 27 1313 4480<strong>MLX</strong>-8 26 2607 8899 13 2607 8899 54 2607 8899384 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!