13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Managing the cooling system 7Fan Speed Hi: 70 - 113state = 1 (FAN_STATE_MED)max_ts_shut_off_count = 1shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP) ===Fan Speed Low: -1 - 60Fan Speed Med: 57 - 70Fan Speed Med-Hi: 67 - 80Fan Speed Hi: 77 - 85state = 0 (FAN_STATE_LOW)max_ts_shut_off_count = 1shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===Fan Speed Low: -1 - 60Fan Speed Med: 57 - 70Fan Speed Med-Hi: 67 - 80Fan Speed Hi: 77 - 95state = 1 (FAN_STATE_MED)max_ts_shut_off_count = 1shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP_CPU) ===Fan Speed Low: -1 - 60Fan Speed Med: 57 - 70Fan Speed Med-Hi: 67 - 80Fan Speed Hi: 77 - 95state = 0 (FAN_STATE_LOW)max_ts_shut_off_count = 1shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Syntax: show fan-thresholdThe output displays the following information.TABLE 50This field...Temperature threshold information for modules <strong>and</strong> fan speedsDisplays...Thermal Sensor Control Block(THERMAL_SENSOR_TEST_RULE_)Fan Speed Low or Med or Med-Hi orHiState = 0 (FAN_STATE_LOW)max_ts_shut_off_countshut_off_count = 0 0 0 0 0 0 0 0The temperature threshold information for the various modules. The parameter indicates the following:• MP – The active management module• STANDBY_MP – The st<strong>and</strong>by management module• SNM – The switch fabric module• LP – An interface moduleThe current setting of the low <strong>and</strong> high temperature thresholds for the low,medium, medium-high, <strong>and</strong> high fan speeds.NOTE: As indicated in Table 49 on page 333, the low fan speed for eachmodule does not have a default low temperature threshold value,nor can you configure this value. The “-1” value that appears in theFan Speed Low field for each module is a <strong>Brocade</strong> internal valueonly.For <strong>Brocade</strong> internal use only.For <strong>Brocade</strong> internal use only.For <strong>Brocade</strong> internal use only.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 33553-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!