13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Managing Routers <strong>and</strong> ModulesChapter7Managing the deviceYou can perform these management tasks for the router:• Enable <strong>and</strong> disable a DC power source, if necessary.• Display status <strong>and</strong> temperatures of all hardware components.• Display the Syslog configuration <strong>and</strong> static <strong>and</strong> dynamic buffers.• Disable <strong>and</strong> re-enable power to interface modulesEnabling <strong>and</strong> disabling a DC Power SourceTo block the router from recognizing a DC power source (<strong>and</strong> as a result, enabling the device torecognize an AC power source), enter the following comm<strong>and</strong> at the global CONFIG level of the CLI:<strong>Brocade</strong>(config)# no use-dc-powerSyntax: no use-dc-powerDisabling <strong>and</strong> re-enabling power to interface modulesYou can disable power <strong>and</strong> re-enable power to all interface modules, or to a specified interfacemodule using the power-off comm<strong>and</strong> in the CLI, as shown in the following example:<strong>Brocade</strong># power-off lp allSyntax: power-off lp [all |]• all - disables power to all interface modules• - disables power to the interface module in the specified slot. You can specify1-4 for 4-slot routers, 1-8 for 8-slot routers, 1-16 for 16-slot routers, <strong>and</strong> 1-32 for 32-slotrouters.NOTEIt is recommended that you do not disable power to interface modules during a software upgrade.If you try to disable power during a software upgrade, the following message will be displayed:Warning: There is an outst<strong>and</strong>ing software download.Do you want to continue ? (enter “y” or “n”)Type “n” <strong>and</strong> wait until the upgrade is complete.To re-enable power to all interfaces or to a specific interface, enter the power-on lp comm<strong>and</strong>, asshown in this example:<strong>Brocade</strong># power-on lpSyntax: power-on lp [all |]<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 32153-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!