13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installing 2x100GbE interface modules in <strong>Brocade</strong> <strong>MLX</strong>e routers 2CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-4, <strong>Brocade</strong> <strong>MLX</strong>e--8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e-16routers with AC <strong>and</strong> DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). Theground wire should have an agency-approved crimped connector (provided with the device)attached to one end, with the other end attached to building ground. The connector must becrimped with the proper tool, allowing it to be connected to both ground screws on the enclosure.Before crimping the ground wire into the provided ground lug, ensure the bare copper wire hasbeen cleaned <strong>and</strong> antioxidant is applied to the bare wire.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-32, routers with AC <strong>and</strong> DC systems, use aground wire of at least 2 American Wire Gauge (AWG). The ground wire should have anagency-approved crimped connector (provided with the device) attached to one end, with theother end attached to building ground. The connector must be crimped with the proper tool,allowing it to be connected to both ground screws on the enclosure. Before crimping the groundwire into the provided ground lug, ensure the bare copper wire has been cleaned <strong>and</strong> antioxidantis applied to the bare wire.Installing 2x100GbE interface modules in <strong>Brocade</strong> <strong>MLX</strong>e routersThis section provides installation instructions for 2x100G interface modules.Installation considerations• 2x100G interface modules cannot be installed in slot 1 of a <strong>Brocade</strong> <strong>MLX</strong> 4-slot or a <strong>Brocade</strong><strong>NetIron</strong> <strong>XMR</strong>4000 chassis. This restriction does not apply to <strong>Brocade</strong> <strong>MLX</strong>e 4-slot devices.• 2x100G modules occupy two adjacent slots. When you install a 2x100G module, the oddnumbered (low number) slot of the slot pair becomes the active slot, <strong>and</strong> the even numberedslot (higher number) is blocked.The acceptable slots in which to install this module are odd-numbered interface module slots(1, 3, 5, 7, 9. 11, 13, <strong>and</strong> 15 for a 16-slot chassis, for example). Adjacent even-numbered slotswill be in blocked state. In all cases, the lower number (odd number) becomes the active slot<strong>and</strong> the higher number (even number) becomes the blocked slot.• 2x100G modules cannot be installed in the following scenarios:- If there is another type of module installed in either of the slots- If either slot is configured as something else. Before you install your 2x100G module, youwill need to reconfigure the slot using the no module comm<strong>and</strong>.• The following conditions will prevent a 2x100G interface module from operating properly:- If either of the two slots required to house the module is already configured for anothertype of module.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 6753-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!