13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installing a <strong>Brocade</strong> <strong>MLX</strong>e-16 router 2DANGERThe intra-building ports of the equipment or subassembly are suitable for connection tointra-building or unexposed wiring or cabling only. The intra-building ports of the equipment orsubassembly MUST NOT be metallically connected to interfaces that connect to the outside plant(OSP) or its wiring. These ports are designed for use as intra-building interfaces only (Type 2 orType 4 ports as described in GR-1089-CORE, Issue 5) <strong>and</strong> require isolation from the exposedOSP cabling. The addition of Primary Protectors is not sufficient protection to connect theseinterfaces metallically to OSP wiring.Table 29 provides the router slot numbers into which you must install the modules. Markings forthe router slots appear at the base of the slots.TABLE 29Module<strong>Brocade</strong> <strong>MLX</strong>e-16 module slot designationsSlot numberManagement modulesActive module – M1 (upper).Redundant module – M2 (lower).Interface modules 1 – 16Switch Fabric modulesSF1 – SF4NOTEIf you are installing a redundant management module, refer to the chapter titled “Using a RedundantManagement Module” in the <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> Family Configuration Guidefor information about how the redundant module works, optional software configurations that youcan perform, <strong>and</strong> how to manage the redundancy feature.NOTE<strong>Brocade</strong> <strong>MLX</strong>e modules are dedicated, which means that you must install them in <strong>Brocade</strong> <strong>MLX</strong>erouters only. If you install a <strong>Brocade</strong> <strong>MLX</strong>e module in another <strong>Brocade</strong> router or install a moduleintended for another <strong>Brocade</strong> router in a <strong>Brocade</strong> <strong>MLX</strong>e router, the router <strong>and</strong> module may notfunction properly.Although management modules are designed to be hot-swappable, you must upgrade the softwareon all interface modules <strong>and</strong> management modules to the appropriate software release beforeinstalling them. For more information on the appropriate software release, refer to the <strong>Hardware</strong>Installation Notes that shipped with the management module.For information about how to disable <strong>and</strong> re-enable power to interface modules, see “Disabling <strong>and</strong>re-enabling power to interface modules” on page 321Before installing modules in the <strong>Brocade</strong> <strong>MLX</strong>e-16 router, have the following items available:• A large flat-blade screwdriver.• A new or replacement interface module, which you can order from <strong>Brocade</strong>• An ESD wrist strap with a plug to attach to the ESD connector on the router chassis.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 9353-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!