13.07.2015 Views

Feasibility Study and Technical Report - Pretivm

Feasibility Study and Technical Report - Pretivm

Feasibility Study and Technical Report - Pretivm

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

13.3.10 SOLIDS LIQUID SEPARATION TESTS WORKIn 2012, Pocock Industrial conducted solids liquid separation (SLS) tests on the flotationconcentrate <strong>and</strong> flotation tailings samples. The test program included sample particlesize analysis, flocculants screening <strong>and</strong> evaluation, static <strong>and</strong> dynamic thickening tests,pulp rheology, <strong>and</strong> filtration studies.The results of the thickening tests are summarized in Table 13.32, Table 13.33, <strong>and</strong>Figure 13.29. To enable the best performance for both flotation concentrate <strong>and</strong>flotation tailings, Hychem AF 304 was selected as the flocculant, which is a medium tohigh molecular weight anionic polyacrylamide, with a 15% charge density.A concentration of approximately 20% is recommended for the flotation concentratethickener feed solids. Using a conventional thickener under the recommendedconditions, the unit area for the concentrate is in the range of 0.19 to 0.24 m 2 /t/d, whilethe underflow solids concentration is from 68 to 72%.Pocock recommended a concentration of approximately 10% for the tailings thickenerfeed solids. Using a conventional thickener under the recommended conditions, the unitarea for tailings is within the range of 0.43 to 0.48 m 2 /t/d, while the underflow solidsconcentration is in the range of 61 to 65%.The recommended hydraulic rate is 5.2 to 6 m 3 /m 2 /h for a high rate concentratethickener, <strong>and</strong> 4.2 to 5.0 m 3 /m 2 /h for a high rate tailings thickener.The maximum design thickener underflow density is suggested to 72% for theconcentrate <strong>and</strong> 65% for the tailings.Table 13.32Conventional Thickening Test Results for Flotation ConcentrateFeedSolids(%)CCDStageSimulatedDose(g/t)FlocculantConcentration(g/L)RiseRate(m 3 /m 2 /h)Maximum TestDensity(%)Time(min)SolidsDensity(%)Unit Area(m 2 /t/d)20 Stage 1 30.0 0.1 6.31 75.7 120 68 70 72 0.21 0.22 0.2420 Stage 1 35.0 0.1 6.83 76.3 120 68 70 72 0.19 0.20 0.2120 Stage 2 30.0 0.1 6.49 75.1 120 68 70 72 0.19 0.21 0.2220 Stage 3 25.0 0.1 6.35 74.4 120 68 70 72 0.19 0.20 0.2120 Stage 1 40.0 0.1 5.26 75.7 150 68 70 72 0.18 0.20 0.2125 Stage 1 35.0 0.1 2.28 76.9 120 68 70 72 0.20 0.21 0.2325 Stage 2 30.0 0.1 2.10 76.4 120 68 70 72 0.21 0.23 0.2425 Stage 3 25.0 0.1 2.27 74.4 120 68 70 72 0.20 0.22 0.2330 Stage 1 35.0 0.1 1.37 77.3 180 68 70 72 0.32 0.35 0.3830 Stage 2 30.0 0.1 1.26 75.7 180 68 70 72 0.31 0.34 0.3730 Stage 3 25.0 0.1 1.20 76.5 180 68 70 72 0.32 0.35 0.38Notes:Flocculant (Hychem AF 304) is a medium to high molecular weight anionic polyacrylamide, with15% charge density.CCD = counter current decantation.Pretium Resources Inc. 13-50 1291990200-REP-R0012-02<strong>Feasibility</strong> <strong>Study</strong> <strong>and</strong> <strong>Technical</strong> <strong>Report</strong> on the BrucejackProject, Stewart, BC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!