13.07.2015 Views

Feasibility Study and Technical Report - Pretivm

Feasibility Study and Technical Report - Pretivm

Feasibility Study and Technical Report - Pretivm

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 16.10Mine Infrastructure Excavations – Ground Support RecommendationsAreaDimension(height x width (alongtrend) by length)(m)Trend/Plunge ofExcavationDesignFactorof Safety Lifespan SupportCap Magazine 3.05 by 6.1 by 3.05 152/21 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.75 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS(shotcrete only required if rehab will not be practical due to installed infrastructure).Crusher Chamber -Lower level(conveyor)Crusher Chamber -Upper level (truck)Electricians <strong>and</strong>Millwrights ShopFuel <strong>and</strong> LubeStationService Bay,Maintenance Bay,<strong>and</strong> Tire Bay18.1 by 14.2 by 9.4 057/01 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.75 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS.Cable bolts:Walls: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacingBack: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacing17.3 by 7.6 by 9.3 057/01 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.5 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS.Cable bolts:Walls: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacingBack: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacing5.5 by 16.2 by 5.5 270/01 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.75 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS(shotcrete only required if rehab will not be practical due to installed infrastructure).4.5 by 35 by 8.5 243/06 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.75 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS(shotcrete only required if rehab will not be practical due to installed infrastructure).Cable bolts:Back: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacing11.5 by 42 by 10.0 005/00 2 LOM Galvanized, resin-grouted rebar (or equivalent); 1.8 m length; 1.75 m square spacing.Welded wire mesh, 100% coverage on back <strong>and</strong> walls, coated with minimum 2" SFRS(shotcrete only required if rehab will not be practical due to installed infrastructure).Cable bolts:Walls: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacingBack: 5.0 m length, bulbed str<strong>and</strong>, 2.5 m square spacingtable continues…Pretium Resources Inc. 16-34 1291990200-REP-R0012-02<strong>Feasibility</strong> <strong>Study</strong> <strong>and</strong> <strong>Technical</strong> <strong>Report</strong> on the Brucejack Project, Stewart, BC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!