180 Appendix A. Tracer User’s Manual<br />

the curve, such as the breakdown voltage <strong>of</strong> a single-junction device. If smoothness is<br />

required, a lower value should be specified. Setting MINCUR below 1X10-15A/µm is<br />

not recommended because Tracer has problems controlling smoothness at such low<br />

currents. Default: 0.0A/µm.<br />

• MINDL is the minimum normalized step size allowed in the trace. Usually the user<br />

does not need to adjust this parameter. Increasing MINDL will reduce the smoothness<br />

<strong>of</strong> the trace by overriding the angle criteria, resulting in more aggressive projection <strong>and</strong><br />

fewer simulation points. Reducing MINDL will enhance the smoothness <strong>and</strong> increase<br />

the number <strong>of</strong> points in the trace. Default: 0.1.<br />

• FREQUENCY specifies how <strong>of</strong>ten the binary output (solution) files <strong>of</strong> the trace are<br />

saved. All I-V points are saved in outputfile. However, the PISCES solution files<br />

corresponding to these points are saved only if they are <strong>design</strong>ated by FREQUENCY.<br />

If FREQUENCY=0, none <strong>of</strong> the solutions is saved, except perhaps the turning points<br />

(see below). If FREQUENCY=5, e.g., the solution file <strong>of</strong> every fifth point will be<br />

saved to files named soln.5, soln.10, etc., along with its PISCES input file (input.5,<br />

input.10, ...) <strong>and</strong> output I-V file (iv.5, iv.10, ...). Default: 0.<br />

• TURNINGPOINTS is either YES or NO. If it is YES, the binary output (solution) file<br />

from PISCES will be saved whenever the slope <strong>of</strong> the I-V curve changes sign, i.e., there<br />

is a turning point. The name <strong>of</strong> the output file is soln.num, where num is the number <strong>of</strong><br />

the current solution. For example, if the 25th point has a different sign than the 24th<br />

point, Tracer will save a file called soln.25. Default: NO.<br />

• VERBOSE is either YES or NO. If it is YES, certain information about each solution<br />

(which the user may not be interested in) is printed in outputfile. The information<br />

consists <strong>of</strong> the external control-electrode voltage, the load resistance on the control<br />

electrode, the slope (differential resistance) <strong>of</strong> the solution, the normalized projected<br />

distance <strong>of</strong> the next simulation I-V point, <strong>and</strong> the normalized angle difference between<br />

the last two simulation points. Default: NO.