5.3 Hardware properties<br />

Example properties are shown below:<br />

Figure 5-3 File Import properties for .par files<br />

To browse, click once on the Value field next to Import file, <strong>and</strong> click the<br />

browse button that appears. Select .par as file type <strong>and</strong> browse to the file.<br />

Filter informs about the type of data is has found at the specified location. It<br />

can be either BURSTware, FLOware or SIZEware.<br />

Selected columns line lists the data types available in the file(s) to import.<br />

You can select all or parts of the list to import. For example, if the files<br />

contain data from a two channel measurement, you can select data from one<br />

of the channels only if you wish. This is specified by tick marks in the drop<br />

down list accessed from the value field.<br />

It is recommended always to include the Status from all processor channels.<br />

File extension specifies the first file to import, if the .par file selected is for<br />

a measurement with multiple positions. Burstware automatically generates<br />

file extensions for the individual positions .000, .001, ... .00a, ...00z, 010,<br />

...ZZZ.<br />

If you are interested in a single position among many, specify the data file’s<br />

extension for that position in the File extension line.<br />

If you are interested in all positions (typically for velocity profile <strong>and</strong> vector<br />

plots), specify .ZZZ as the Last file (extension).<br />

If you are only interested in the file specified in the File extension line,<br />

leave the Last file (extension) blank.<br />

If Validate Samples is Yes/On, only valid samples will be imported.<br />

The <strong>BSA</strong> F/P Application controls hardware communication <strong>and</strong> data<br />

acquisition, <strong>and</strong> the measurement positions, the traverse mesh. The left h<strong>and</strong><br />

part of the window controls the hardware settings. The properties of the<br />

hardware are displayed in the Property editor upon selection of the hardware<br />

in the Device list. These properties are explained in section 5.3 to 5.7.2.<br />

The generation of measurement positions, <strong>and</strong> the linking between these <strong>and</strong><br />

hardware settings takes place in the right h<strong>and</strong> part of the window. This is<br />

described in section 5.7.8.<br />

All properties are accessed from the <strong>BSA</strong> Application window:<br />

5-6 <strong>BSA</strong> <strong>Flow</strong> <strong>Software</strong>: Project explorer objects