Receiving probe<br />

orientation If the cloud of particles is slightly tilted relatively to the acceptance b<strong>and</strong>,,<br />

the orientation <strong>and</strong> position of the receiving probe should be checked. It<br />

might be that the transmitting <strong>and</strong> receiving probes are note in the same<br />

plane or that the receiving probe is rotated around its optical axis.<br />

Focus of receiving<br />

Figure 8-8: Bad orientation of the receiving optics or the receiving <strong>and</strong><br />

transmitting optics are not in the same plane.<br />

probe Invalid particles along a horizontal line might indicate that the receiving<br />

probe is not correctly focused. Check the alignment of the receiving probe.<br />

<strong>BSA</strong> <strong>Flow</strong> <strong>Software</strong>: Trouble shooting 8-9