Cycle length<br />

The property Cycle length can be set to either in degree (angle binning) or<br />

in time (Time binning). With time binning, the Cycle length is the time<br />

between two reset pulses <strong>and</strong> with angle binning, . It determines whether the<br />

time between two Reset-pulses should be interpreted as 360° (default) or<br />

720°, the latter being relevant for example in four stroke engines, where one<br />

full cycle correspond to two revolutions of the crankshaft.<br />

Note: Please note that Cycle length = 720 deg does not accept two reset-pulses<br />

within each cycle, even if a full cycle corresponds to two revolutions of the<br />

crankshaft: There is no way to tell, which reset-pulse indicates the start of a<br />

cycle, <strong>and</strong> which one is a “halfway marker”. Instead the shaft encoder<br />

should be connected to the camshaft, or a 2:1 gearing mounted between the<br />

crankshaft <strong>and</strong> the encoder, to yield only one reset pulse per cycle.<br />

Sub-cycles<br />

Synchronisation mode<br />

The property Sub-cycles is an integer with the default value 1. It is<br />

typically used for measurements on propellers <strong>and</strong> the like, where the<br />

number of sub-cycles correspond to the number of blades on the<br />

propeller.<br />

Figure 6-45 Sub-cycles = 3 for same data as in Figure 6-41<br />

In the example in Figure 6-45 the 3 blades are merged into one, with a<br />

resulting full cycle length of 360°/3 = 120°.<br />

The property Synchronisation mode is a read-only property indicating<br />

whether phase sorting is done on the basis of arrival time or encoder pulses.<br />

The property is set to Encoder count if Reset Encoder <strong>and</strong> Encoder inputs are<br />

enabled, <strong>and</strong> to Internal clock if Reset Encoder is not enabled, meaning that<br />

the phase sorting is done based on arrival time.<br />

If both Reset Encoder <strong>and</strong> Sync 1 are enabled, the synchronisation mode is<br />

set to Encoder count.<br />