Note An important point is that, in order to maximize the accuracy of the concentration<br />

measurement, the main flow direction should be parallel to the X axis.<br />

7.2.2 The concept of the DualPDA<br />

Although phase Doppler anemometry is a well established technique for<br />

measuring size <strong>and</strong> velocity of spherical particles, there exist some principle<br />

difficulties with the measurement of large particles, in particular when the<br />

system is set up to detect refractively scattered light, as is usually the case in<br />

spray investigations. Large in this connection means that the particle<br />

diameter exceeds about one third of the diameter of the measurement<br />

volume. In such cases erroneous size measurements may lead to a<br />

significant reduction of accuracy in estimating volume weighted flux <strong>and</strong><br />

concentration, since the volume is proportional to the third power of<br />

diameter.<br />

Two effects have been identified as potentially leading to incorrect size<br />

measurements in such applications:<br />

• The trajectory effect (or Gaussian beam effect) <strong>and</strong><br />

• The slit effect.<br />

Both effects arise when the PDA system is set up to receive refractively<br />

scattered light, as is typical for applications to sprays, but instead receives<br />

reflectively scattered light. Those signals are then also processed with the<br />

phase-diameter relationship based on refraction <strong>and</strong> thus lead to incorrect<br />

size measurements.<br />

Note The use of three detectors will not ensure that these effects are suppressed.<br />

Furthermore, it is not possible to generalize the magnitude or sense of the error,<br />

i.e. it may be positive or negative, depending on the exact operating conditions<br />

<strong>and</strong> droplet diameter.<br />

Since the droplet diameter enters the mass flux computation to the third<br />

power, erroneous size measurements may seriously affect the accuracy of the<br />

mass flux computation, even if the size of only very few droplets is<br />

measured incorrectly.<br />

In a number of applications the performance <strong>and</strong> the accuracy of the<br />

conventional PDA systems (ClassicPDA <strong>and</strong> FiberPDA) are therefore not<br />

satisfying. This is particularily the case for spray investigations. As already<br />

mentioned, the physical reasons for the shift between refractively <strong>and</strong><br />

reflectively scattered light in such applications are the trajectory effect <strong>and</strong><br />

the slit effect.<br />

7-30 <strong>BSA</strong> <strong>Flow</strong> <strong>Software</strong>: Reference guide