Peer-to-peer connection<br />

Processor software version 2.40 <strong>and</strong> higher<br />

Select<br />

IP Address Subnet Mask Comment<br />

ion<br />

0 10.10.100.100 255.0.0.0 System defaults.<br />

1 10.10.100.101 255.0.0.0 .<br />

2 10.10.100.102 255.0.0.0 .<br />

3 10.10.100.103 255.0.0.0 .<br />

4 . . Not used.<br />

5 . . Not used.<br />

6 . . Not used.<br />

7 192.168.255.254 255.0.0.0 <strong>Flow</strong>Map processor.<br />

8 10.10.100.34 255.0.0.0 .<br />

9 10.10.100.30 255.0.0.0 .<br />

10 0.0.0.0 255.0.0.0 DHCP Server support.<br />

11 . . Not used.<br />

12 #.#.#.# #.#.#.#<br />

User defined in Configuration<br />

Service.<br />

13 Do not use.<br />

14 . . Do not use.<br />

15 . . Not used.<br />

It is recommended that systems running with the <strong>BSA</strong> Processor run peer-topeer<br />

with the application PC. This is primarily because of performance <strong>and</strong><br />

service considerations. When the processor <strong>and</strong> computer are connected<br />

peer-to-peer the two parts have to have nearly the same IP address <strong>and</strong><br />

subnet masks. Valid combinations for the application PC are:<br />

Version 1.00 Version 2.00<br />

10.10.x.x<br />

255.255.0.0<br />

10.x.x.x<br />

255.0.0.0<br />

Caution The <strong>BSA</strong> comes with a red peer-to-peer Ethernet cable (crossed wire cable).<br />

Do not use the peer-to-peer Ethernet cable to connect to a network, since the<br />

pin connections are different for point-to-point <strong>and</strong> normal network<br />

connection.<br />

Configuration Service<br />

Another way to change the IP address, subnet mask <strong>and</strong> processor name is to<br />

use the advanced Configuration Service installed in the processor. This<br />

service can be reached using an existing network connection or by a serial<br />

null-modem cable connection.<br />

When using a network connection, communication can be established using<br />

the Telnet utility. In the case of a serial connection the program<br />

HyperTerminal can be used. Both programs are found in st<strong>and</strong>ard<br />

installations of Windows. A quick way to use the Configuration Service is to<br />

launch communication from the Connection page in the Device<br />

Configuration.<br />