14.03.2015 Views

AT Commands Reference Manual - wireless netcontrol GmbH

AT Commands Reference Manual - wireless netcontrol GmbH

AT Commands Reference Manual - wireless netcontrol GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 3: <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong><br />

Antenna Type Change of State Delay of ANT_DET Pin<br />

HIA (High Impedance) N => D or D => N Delayed<br />

N => G or G => N<br />

D => G or G => D<br />

Immediate<br />

Immediate<br />

Command<br />

Type Syntax Response/Action Remarks<br />

Execute <strong>AT</strong>S97 OK Deprecated; Implemented only for<br />

backward compatibility with older<br />

Motorola modules.<br />

Read <strong>AT</strong>S97? <br />

OK<br />

or:<br />

+CME ERROR: <br />

The Read command indicates antenna<br />

connection status.<br />

Note: When antenna type is unknown (factory default state), an error will be returned to read<br />

command.<br />

The following table shows the <strong>AT</strong>S97 parameters.<br />

Table 3-123: <strong>AT</strong>S97 Parameters<br />

<br />

Description<br />

000 The antenna is not connected<br />

001 The antenna is connected<br />

002 The antenna is grounded<br />

Example<br />

// Connect the antenna<br />

<strong>AT</strong>S97?<br />

001<br />

<strong>AT</strong>S97<br />

OK<br />

<strong>AT</strong>S97=?<br />

ERROR<br />

// Disconnect the antenna<br />

<strong>AT</strong>S97?<br />

000<br />

April 15, 2010 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> 3-193