GPRS/EDGE/UMTS<br />

The following table shows the command's parameters and returned results.<br />

Table 3-198: +MIPCALL Parameters<br />

<br />

CallID<br />

operation<br />

CID<br />

Description<br />

A unique number that identifies a call in 0-2 range. Call ID value in 1-2 range<br />

represents a valid Call ID and can be used for +MIPCALL set command type. Call ID<br />

value 0 is used in +MIPCALL read command type and responses, when no active call<br />

found.<br />

0 - close a Network Call<br />

1 - open a Network Call<br />

2 - open a Circuit Switched Call 1<br />

PDP Context Identifier in 0-16 range. 1-16 range is valid PDP CID values, 0 - value<br />

represents invalid CID 2 .<br />

Phone Number Phone number of CSD service provider (in quotation marks) 3 up to 64 characters. 1<br />

Local IP<br />

Call Status<br />

IP address given by the network service provider.<br />

0 - Closed<br />

1 - Opened<br />

Note: 1 ) The feature will be implemented later.<br />

2 ) Zero CID value will be used in<br />

+MIPCALL command set case as CID parameter when CSD based call activation<br />

requested.<br />

+MIPCALL command read case, when CSD-based active call found.<br />

3 ) Contact your service provider for details.<br />

Example<br />

<strong>AT</strong>+MIPCALL?<br />

+MIPCALL: 0,0<br />

<strong>AT</strong>+MIPCALL=1,1,1<br />

OK<br />

+MIPCALL: 1,1,"172.16.157.152"<br />

<strong>AT</strong>+MIPCALL=2,1,2<br />

OK<br />

+MIPCALL: 2,1,"172.16.1.34"<br />

<strong>AT</strong>+MIPCALL?<br />

+MIPCALL: 1,1,"172.16.157.152"<br />

+MIPCALL: 2,2,"172.16.1.34"<br />

OK<br />

3-316 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> April 15, 2010