UI (User Interface)<br />

The following table shows the +CSIM parameters.<br />

Table 3-181: +CSIM Parameters<br />

<br />

<br />

Description<br />

Integer type. Length of the characters that are sent to TE in or<br />

string (two times the actual length of the or ).<br />

Command passed on by the MT to the SIM in the format as described in GSM 51.011.<br />

Hexadecimal character format.<br />

Maximum length: 520 characters (260 bytes).<br />

<br />

Response to the command passed on by the SIM to the MT in the format as described<br />

in GSM 51.011. Hexadecimal character format.<br />

Maximum length: 516 characters (258 bytes).<br />

Note: Hexadecimal characters in and are uppercase.<br />

Example<br />

// Read record 1 in EF ADN (6F3A) in UICC card.<br />

<strong>AT</strong>+CSIM=14,"00A40004027F10" // SELECT DF TELECOM<br />

+CSIM: 4,"6122"<br />

// Command successful.<br />

OK<br />

<strong>AT</strong>+CSIM=14,"00A40004026F3A" // SELECT EF ADN<br />

+CSIM: 4,"6120"<br />

// Command successful.<br />

OK<br />

<strong>AT</strong>+CSIM=10,"00B201041E" // READ RECORD 1, 0x1E length.<br />

+CSIM: 64,"4245545441FFFFFFFFFFFFFFFFFFFFFF06913355555555FFFFFFFFFFFFFF9000"<br />

// Command successful. Response length is 32 bytes including status words.<br />

OK<br />

+CIND, Indicator Control<br />

This command is used to query the status of various ME indicators.<br />

Command<br />

Type Syntax Response/Action Remarks<br />

Read <strong>AT</strong>+CIND? +CIND:,…. Read command returns the<br />

status of ME indicators.<br />

Test <strong>AT</strong>+CIND=? +CIND:(,(list of supported<br />

s)),(,(list of<br />

supporteds))…<br />

Test command returns pairs,<br />

where string value is<br />

a short description of the indicator<br />

and compound value is<br />

the allowed values for the<br />

indicator.<br />

3-274 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> April 15, 2010