Chapter 3: <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong><br />

&F, Set to Factory Defined Configuration<br />

This command restores the factory default configuration profile. The H24 supports only one<br />

factory default profile, 0.<br />

Command Type Syntax Response/Action Remarks<br />

Set <strong>AT</strong>&F OK<br />

or:<br />

+CMS ERROR: <br />

Read <strong>AT</strong>&F? <br />

Test<br />

The Test command for &F is not<br />

defined by ITU, and therefore is not<br />

supported by the H24. The H24 returns<br />

an error.<br />

The following table shows the &F parameters.<br />

Table 3-166: &F Parameters<br />

<br />

Description<br />

0 Factory default configuration profile. This is the only value supported.<br />

Example<br />

<strong>AT</strong>&F?<br />

&F: 0<br />

OK<br />

Z, Reset to Default Configuration<br />

This command drops the current call, and resets the values to default configuration.<br />

Command Type Syntax Response/Action Remarks<br />

Set <strong>AT</strong>Z OK<br />

or:<br />

+CMS ERROR: <br />

Read<br />

Test<br />

The Read command for Z is not<br />

defined, and therefore is not supported<br />

by the H24. The H24 returns an error.<br />

The Test command for Z is not<br />

defined, and therefore is not<br />

supported by the H24. The H24<br />

returns an error.<br />

April 15, 2010 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> 3-247