Chapter 3: <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong><br />

Example<br />

<strong>AT</strong>&Y0<br />

OK<br />

<strong>AT</strong>&Y1<br />

OK<br />

Sleep Mode <strong>Commands</strong><br />

In order to improve the power consumption, the H24 supports a low-power consumption mode,<br />

called "Sleep mode". The H24 has internal decision conditions for entering and exiting sleep<br />

mode. As the terminal and the H24 operate in a combined system, and as the communication<br />

between the H24 and the terminal must be reliable, there should be a mechanism agreed upon by<br />

both the H24 and the terminal to co-ordinate their separate sleep mode entering and exiting<br />

sequences. The H24 will not enter sleep mode unless the terminal enables the H24 sleep mode<br />

and signals its readiness for sleep. For this purpose, a set of <strong>AT</strong> commands and dedicated HW<br />

lines are defined.<br />

Notes:<br />

1. H24 USB supports resume/suspend mechanism according to USB2.0 specification,<br />

which handles signaling (resume/suspend, remote wakeup) and data integrity.<br />

2. If the following conditions become true:<br />

- Sleep mode enabled<br />

- HW flow control enabled<br />

- Airplane mode enabled (<strong>AT</strong>+CFUN=0 or <strong>AT</strong>+CFUN=4).<br />

The user will be able to wake H24 through RX activity only if the terminal switches<br />

to flow control NONE first!<br />

Enable/Disable Sleep Mode<br />

Enabling/Disabling sleep mode is controlled via +MSLEEP command.<br />

Issue <strong>AT</strong>+MSLEEP=1 for enabling sleep mode or <strong>AT</strong>+MSLEEP=0 for disabling.<br />

Sleep Mode <strong>AT</strong> <strong>Commands</strong><br />

The following are the Sleep mode <strong>AT</strong> commands:<br />

• <strong>AT</strong>S102: Defines the period to wait between sending the wake-up signal, and sending data to<br />

the terminal.<br />

• <strong>AT</strong>S100: The minimum time that takes the Terminal to enter sleep mode. Only if this time<br />

period passes, the H24 will wait <strong>AT</strong>S102 time between wake-up out line and data<br />

transmission.<br />

The following are applicable for UART only:<br />

• <strong>AT</strong>S24: Number of Seconds Delay for UART to enter sleep.<br />

• <strong>AT</strong>+MSCTS: Defines the behavior of the CTS line when H24 is in Sleep mode. It enables or<br />

disables activation of the CTS line after wakeup.<br />

April 15, 2010 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> 3-251