Chapter 3: <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong><br />

The following table shows the +CCWA parameters.<br />

Table 3-9: +CCWA Parameters<br />

<br />

Description<br />

Enables/disables the call waiting indication to the terminal by the H24.<br />

0 - Disable<br />

1 - Enable<br />

The default is 0.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Call waiting service request to the network. When the parameter is not given,<br />

the network is not interrogated.<br />

0 - Disable<br />

1 - Enable<br />

2 - Query status<br />

Sum of integers each representing a class of information.<br />

1 - Voice<br />

2 - Data - refers to all bearer services<br />

4 - Fax<br />

16 - Data circuit sync<br />

32 - Data circuit async<br />

The default value is 255.<br />

Calling line number. The number format is specified by .<br />

Type of address octet in integer format:<br />

145 - Default when the dialing string includes the international access code character<br />

"+".<br />

129 - Default when making a local call.<br />

128 - Type of number is unknown (usually the output when the number itself is<br />

unknown)<br />

Call waiting support by the network (output for =2).<br />

0 - Not active<br />

1 - Active<br />

Name of the calling party (if provided by the network or if the number is found in the<br />

H24 phone books).<br />

The Validity of the Calling Line Identity presentation:<br />

0 - CLI valid.<br />

1 - CLI has been withheld by the originator.<br />

2 - CLI is not available due to networking problems or limitations of the originating<br />

network.<br />

Note: When the parameter is 2 (Query status), the first parameter is ignored and the<br />

third parameter is always treated as class = 7.<br />

Example<br />

<strong>AT</strong>+CCWA=1<br />

OK<br />

<strong>AT</strong>+CCWA=?<br />

+CCWA: (0,1)<br />

OK<br />

//Enable call waiting on H24<br />

April 15, 2010 H24 - <strong>AT</strong> <strong>Commands</strong> <strong>Reference</strong> <strong>Manual</strong> 3-23