Access<br />

+CPWD, Change Password<br />

This command sets a new password for the facility lock.<br />

A password can be changed only if the provided password has been verified. The<br />

entered password must also comply with the password rules. The facility value <br />

is not case-sensitive. In the pass-word value, letters are not allowed.<br />

Note: Changing of SIM facility requires that the facility will be enabled (Refer to “+CLCK,<br />

Facility Lock” on page 3-221).<br />

Command<br />

Type Syntax Response/Action Remarks<br />

Set<br />

<strong>AT</strong>+CPWD=,<br />

,<br />

<br />

OK<br />

or:<br />

+CME ERROR: <br />

The Set command sets a new password for<br />

the facility lock function, defined by the<br />

+CLCK command. (Refer to “+CLCK,<br />

Facility Lock” on page 3-221).<br />

Read +CPWD? +CME ERROR: <br />

Test +CPWD=? +CPWD:list of<br />

supported<br />

(,)s<br />

OK<br />

or:<br />

+CME ERROR: <br />

The Test command returns a list of pairs<br />

which represent the available facilities, and<br />

the maximum length of their passwords.<br />

The following table shows the +CPWD parameters.<br />

Table 3-146: +CPWD Parameters<br />

<br />

<br />

<br />

<br />

<br />

Description<br />

List of supported facilities. All the facility messages, except for SC and P2, are sent to<br />

the network. (The facilities are not case-sensitive.)<br />

SC SIM (lock SIM card)<br />

The SIM requests the password during H24 power-up and when this command is<br />

issued.<br />

AB All Barring services. Facility messages of barring services are sent to the<br />

network.<br />

P2 SIM PIN2.<br />

String type, 4-8 character password specified for the facility from the H24 user<br />

interface.<br />

String type, 4-8 character new password specified by the user.<br />

Maximum length of the facility password. Integer type.<br />

Example<br />

<strong>AT</strong>+CPWD =?<br />

+CPWD: ("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),<br />

("SC",8),("P2",8)<br />