the SB with a 2.5 mm balloon; ii) opening of the MB access by deploying a 3 mm<br />

balloon through the struts of the first device; iii) expansion of the second device across<br />

ostium of the SB; iv) FKB procedure by simultaneously expanding a 3 mm balloon in<br />

the MB and a 2.5 mm balloon in the SB.<br />

3.2 Fluid dynamic model<br />

The fluid domains were created starting from the final geometrical configurations of the<br />

structural simulations [5]. In order to obtain accurate results on 3D complex geometries<br />

in the shortest time compatible with computational resources available, a hybrid mesh<br />

method is applied using ANSYS ICEM CFD 13 (Ansys Inc., Canonsburg, PA, USA)<br />

[6]. This method uses both hexahedral and tetrahedral elements. Hexahedral elements<br />

should be preferred because of higher accuracy and reduced number of elements for a<br />

certain volume. Nevertheless, hexahedral elements are difficult to use in highly complex<br />

A<br />

B C<br />

Figure 1. A) Uncrimped configurations of the investigated stents. Left: dedicated device (Tryton) Right:<br />

standard device resembling the Multilink Vision. B) CAD model of a 45 degrees coronary bifurcation. In<br />

the magnification area, the stratification of the arterial wall in the adventitia, media and intima layers is<br />

shown. C) Deflating (top) and bending (bottom) procedures of a cylindrical angioplasty balloon.<br />

A<br />

1 2<br />

3 4<br />

5<br />

Figure 2. Steps of the culotte technique performed with a dedicated and standard stent (A) and with two<br />

standard devices (B): 1) positioning of the SB stent by inflating a 2.5 mm cylindrical balloon; 2) opening<br />

of the MB access by crossing and deploying a 3 mm cylindrical balloon through the struts of the SB<br />

device; 3) positioning and deployment of the second device in the MB across the bifurcation; 4) Final<br />

Kissing Balloon procedure with a 3 mm balloon and a 2.5 mm balloon in the MB and SB respectively and<br />

5) final configuration achieved. All the balloons are inflated at 15 atm.<br />

B<br />

1 2<br />

3 4<br />

5