27.12.2012 Views

ARUP; ISBN: 978-0-9562121-5-3 - CMBBE 2012 - Cardiff University

ARUP; ISBN: 978-0-9562121-5-3 - CMBBE 2012 - Cardiff University

ARUP; ISBN: 978-0-9562121-5-3 - CMBBE 2012 - Cardiff University

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

We conclude that the model developed is able to predict the haptic feeling of stability of<br />

a surgical guide and therefore has the potential to allow the user to design for each<br />

procedure the surgical guide that will be the most stable one for this specific patient<br />

anatomy.<br />

ACKNOWLEDGEMENTS<br />

Joyce Van den Broeck acknowledges the Baekeland scheme of the agency for<br />

Innovation by Science and Technology (IWT) for financial support.<br />

REFERENCES<br />

[1] Brown, G. A., Firoozbakhsh, K., De Coster, T. A., Reyna, J. R.J., and Moneim, M., Rapid<br />

prototyping: The future of trauma surgery?, J Bone Joint Surg Am, 2003, Vol. 85-A (Suppl. 4), 49-<br />

55.<br />

[2] Raaijmaakers, M. et al., A custom-made guide-wire positioning device for hip surface replacement<br />

arthroplasty: description and first results, BMC Musculoskel Dis, 2010, Vol. 11 (161), 1-7.<br />

[3] Oka, K. et al., Corrective osteotomy for malunited intra-articular fracture of the distal radius using a<br />

custom-made surgical guide based on three-dimensional computer simulation: case report, Clin<br />

Orthop Relat Res, 2011, Vol. 469 (6), 1766-1773.<br />

[4] Radermacher, K. et al., Computer-assisted orthopaedic surgery with image-based individual<br />

templates, Clin Orthop Relat Res, 1998, Vol. 354, 28-38.<br />

[5] Al-Harbi, S. A. and Sun, A. Y., Implant placement accuracy when using stereolithographic template<br />

as a surgical guide: preliminary results, Implant Dent, 2009, Vol. 18 (1), 46-56.<br />

[6] Goffin, J. et al., Three-dimensional computed tomography-based personalized drill guide for<br />

posterior cervical stabilization at C1-C2, Spine, 2001, Vol. 26 (12), 1343-1347.<br />

[7] Hafez, M. A., Chelule, K. L., Seedhom, B. B., and Sherman, K. P., Computer-assisted total knee<br />

arthroplasty using patient-specific templating, Clin Orthop Relat Res, 2006, Vol. 444, 184-192.<br />

[8] Koeck, F. X. et al., Evaluation of implant position and knee alignment after patient-specific<br />

unicompartmental knee arthroplasty, Knee, 2011, Vol. 18 (5), 294-299.<br />

[9] Miyake, J. et al., Distal radius osteotomy with volar locking plates based on computer simulation,<br />

Clin Orthop Relat Res, 2008, Vol. 469 (6), 1766-1773.<br />

[10] Birnbaum, K et al., Computer-assisted orthopaedic surgery with individual templates and<br />

comparison to conventional operation method., Spine, 2001, Vol. 26 (4), 365-370.<br />

[11] Lu, S. et al., A novel computer-assisted drill guide template for lumbar pedicle-screw placement: a<br />

cadaveric and clinical study., Int J Med Robot Comp, 2009, Vol. 5 (2), 184-191.<br />

[12] Van Brussel, K., Medical image based personalised drill guides for spinal screw insertion, PhD<br />

Thesis, KU Leuven, Leuven, 2002.<br />

[13] Lin, Q., Burdick, J. W., and Rimon, E., A stiffness-based quality measure for compliant grasps and<br />

fixtures, IEEE T Robotic Autom, 2000, Vol. 16, 675-688.<br />

[14] Ma, B. and Ellis, R., Analytic expressions for fiducial and surface target registration error, in<br />

Medical Image Computing and Computer-Assisted Intervention - MICCAI 2006, R. Larsen, M.<br />

Nielsen, and J. Sporring, Eds., 2006, LNCS 4191, 637-644.<br />

[15] Radermacher, K., Compüterunterstützte Operationsplanung und -ausführung mittels individueller<br />

Bearbeitungsschablonen in der Orthopädie, PhD Thesis, RWTH, Aachen, 1999.<br />

[16] Kim, J. O. and Khosla, P. K., "Dexterity measures for design and control of manipulators," in<br />

Intelligent Robots and Systems '91. 'Intelligence for Mechanical Systems, Proceedings IROS '91.<br />

IEEE/RSJ International Workshop on, 1991, 758-763.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!