04.03.2013 Views

Manual

Manual

Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Manual</strong> – TopCon TC.GSS<br />

Installation and commissioning<br />

Commissioning<br />

Electromagnetic compatibility<br />

TopCon TC.GSS power supplies have interference protection and<br />

suppression filters on all power and signal connections such that, on<br />

correct installation, compliance is achieved with the applicable IEC and<br />

EN standards in relation to interference.<br />

The following standards are applicable:<br />

Interference immunity: EN 61000-6-2<br />

Interference emission: EN 61000-6-4<br />

For the interference protection components to be able to perform their<br />

function, the following conditions must apply:<br />

Large area earthing suitable for EMI.<br />

Shield mains and load connection.<br />

(Depending on load and installation situation)<br />

Connect both ends of shields to earth.<br />

(Depending on load and installation situation)<br />

Interference immunity<br />

The system must be fully earthed (encompassing all parts) and earthed<br />

suitable for EMI.<br />

Correct earthing and shielding of the cable connections are key<br />

elements for interference immunity.<br />

All cable shields must be connected to earth potential at both<br />

ends using large area connections.<br />

Ideally shielded connectors are used that are earthed directly via<br />

the earthed sockets on the electrical power supply.<br />

Star topology earthing (suitable for EMI) of the device.<br />

Interference suppression<br />

TopCon TC.GSS power supplies have integrated interference suppression.<br />

For the interference protection components to be able to perform<br />

their function, the following conditions must apply:<br />

Large area earthing suitable for EMI.<br />

Shield mains and load connection.<br />

Depending on load and installation situation.<br />

Connect both ends of shields to earth.<br />

Depending on load and installation situation.<br />

2011-10-18 111 / 298 V00.05b<br />