<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

Group error: D) Configuration (continued)<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

14-9 D8) All slave ID's<br />

have to be<br />

numbered<br />

without a gap<br />

14-10 D9) All HMI/RCU<br />

ID's have to<br />

be numbered<br />

without a gap<br />

14-11 DA) Number of<br />

slaves does<br />

correspond<br />

with the giv-<br />

en value<br />

14-12 DB) Number of<br />

multiload<br />

modules<br />

does not correspond<br />

with<br />

the given<br />

value<br />

14-13 DC) Invalid slave<br />

ID (out of<br />

range)<br />

14-14 DD) Invalid<br />

HMI/RCU ID<br />

(out of range)<br />

14-15 DE) TCLIN ID<br />

invalid<br />

14-16 DF) TCLIN ID not<br />

unique<br />

Description<br />

The module IDs are<br />

not sequential<br />

The HMI IDs are not<br />

sequential<br />

Total number of devices<br />

does not match<br />

the data specified<br />

Module ID for a slave<br />

outside the valid range<br />

HMI ID outside the<br />

valid range<br />

Master detecting<br />

invalid TCLIN ID<br />

Master detecting<br />

several TCLIN with<br />

same ID<br />

Possible reason<br />

Measure to rectify<br />

10.2.2.15. Error group E) Not def.(group 14)<br />

Group error: E) Not def.(group 14)<br />

Flas<br />

hing<br />

code<br />

TopControl/HMI<br />

indication<br />

Description<br />

10<br />

All module IDs must be sequential. For information<br />

on the meaning of sequential, see multiunit<br />

system chapter (for a parallel configuration,<br />

sequential means e.g. ID [hexadecimal] = 00,<br />

10, 20, ...)<br />

The value 'uiCAN_MaxNumModuleParallel' must<br />

be set identically in all modules. Default: 8.<br />

All HMI IDs must be sequentially numbered<br />

starting with 1.<br />

See above, error D6/D7)<br />

It is not possible to connect more than 8 devices<br />

in series or on parallel<br />

Configure the ID via the HMI.<br />

Check IDs for the TCLIN individually / set<br />

Check IDs for the TCLIN individually / set<br />

Possible reason<br />

Measure to rectify<br />

Errors in group E) do not currently exist and are for further additions.<br />