<strong>Manual</strong> – TopCon TC.GSS<br />

Single device operation – special aspects<br />

Internal system status and troubleshooting<br />

4.3.5.2. Indications on DEVICE and CONTROL LEDs<br />

State of the device<br />

DEVICE and CONTROL LEDs on the front of the device<br />

“READY” “STATUS” “ERROR”<br />

2011-10-18 52 / 298 V00.05b<br />

4<br />

“CV”; ”CC”<br />

and “CP”<br />

Power UP OFF ON OFF OFF<br />

STOP ON ON OFF OFF<br />

READY ON FLASHING 3) OFF OFF<br />

RUN ON 1) OFF OFF ON 2)<br />

warn ON 1) FLASHING 3) OFF ON 2)<br />

Error ON OFF 4)<br />

FATAL ERROR 5) FLASHING 5) FLASHING 5)<br />

FLASHING<br />

3)<br />

FLAS-<br />

HING 5)<br />

Table 21 Indication of the system status via LED indication (front).<br />

1 Flashing, if a discharge device is active.<br />

2 One of the three LEDs, as per the actual control mode.<br />

3 Flashing code as per the error table or warning table<br />

(see chapter on troubleshooting).<br />

4 Flashing, if a warning is active at the same time.<br />

5 The three LEDs are flashing together: internal communication failed.<br />

Description of the shutdown process<br />

OFF<br />

OFF<br />

Changing the position of the main switch does not shut down the<br />

TC.GSS power supply immediately, instead a shutdown process is initiated.<br />

In particular, the discharge of the internal capacitors takes a certain<br />

amount of time during which the device is still live internally and to<br />

some extent the outputs are still live.<br />

As long as the shutdown process is running:<br />

The three DEVICE LEDs form a running light.<br />

The HMI display indicates “shutting down…”<br />

For this reason it imperative to wait until this process is complete before<br />

undertaking further tasks on the device.<br />

On devices with 10 and 16 kW the shutdown process is so fast that<br />

there is no indication and no delays.