<strong>Manual</strong> – TopCon TC.GSS<br />

4.3.3. Interlock output inhibit<br />

Single device operation – special aspects<br />

Interlock output inhibit<br />

TopCon TC.GSS power supplies have a feature for rapidly inhibiting the<br />

output using an interlock signal.<br />

All external EMERGENCY STOP contacts must close the interlock circuit<br />

for operation to be possible.<br />

+24VDC<br />

Interlock<br />

COM<br />

0VDC<br />

24<br />

Interlock<br />

2011-10-18 48 / 298 V00.05b<br />

COM<br />

0VDC<br />

Fig. 26 Example interlock circuit on the interface X105.<br />

-1- External EMERGENCY STOP button with internal voltage source.<br />

-2- External EMERGENCY STOP switch with external voltage source.<br />

With interrupted interlock circuit<br />

The power stage is switched off directly<br />

via a hardware link.<br />

The controller remains switched on.<br />

The device changes to the state: “Error”.<br />

To work using the TC.GSS power supply (or a system with TopCon modules),<br />

check that the interlock circuit is actually closed.<br />

Ensure that the correct dummy plug has been used for the termination of the<br />

interface X101.<br />

For further information see chapter 4.3.2.1, page 46.<br />

The description of the interlock circuit for multi-unit systems is different due to<br />

the utilisation of the interface X102 for the different devices in the system.<br />

For further information see Fig. 31, Seite 60.<br />

4.3.4. Interlock circuit with X101 and X105<br />

Ring structure of the interlock circuit<br />

The interlock circuit makes it possible to setup a safety infrastructure.<br />

The basis for the function is an electrical ring structure that must be<br />

closed for operation.<br />

Safety elements -2- (e.g. EMERGENCY STOP buttons) can interrupt<br />

the ring and as a result switch off the TopCon power supply.<br />

For higher safety requirements, e.g. safety class 1, the option: ISR (Integrated<br />

Safety Relay) is available.<br />

For further information see chapter 5.2.2, Seite 77.<br />