<strong>Manual</strong> – TopCon TC.GSS<br />

Main screen – DISPLAY 1<br />

1<br />

Operation of the HMI (option)/RCU (option)<br />

Main screen – DISPLAY 1<br />

Status:<br />

0.2 V<br />

0 A<br />

15.9 kW<br />

Ready<br />

0.2 V<br />

2 A<br />

15.9 kW<br />

2 5<br />

4 3<br />

Status:<br />

FGen [V]<br />

FGen [A]<br />

FGen [kW]<br />

Ready<br />

0.2 V<br />

2 A<br />

15.9 kW<br />

Fig. 75 Main screen without (DISPLAY 1), left, and<br />

with enabled and activated TFE option (DISPLAY 2), right<br />

Main screen without/with enabled option TFE – DISPLAY 1, 2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Status line<br />

The system state is displayed:<br />

Ready: Device is ready for operation, the output is electrically isolated<br />

and the power semiconductor is inhibited.<br />

Running: Device is in operation, the output is providing power.<br />

If a load is connected current flows.<br />

Warning: Device is still in operation, warning limit is exceeded, an<br />

error may be approaching, e.g. over-temperature.<br />

Indication: warning in the message bar -2-.<br />

Error: Device is not ready for operation, the output is electrically<br />

isolated and the power semiconductor is inhibited.<br />

Indication: error in the message bar -2-<br />

Stop: Is generated by the TopControl application on an update to<br />

the firmware for the TC.GSS power supply.<br />

The control electronics are inhibited. The output is electrically<br />

isolated and the power semiconductor is inhibited.<br />

After the update the device must be switched off briefly via<br />

the circuit breaker and then switched back on again.<br />

Message bar<br />

Short description in case of error messages and warnings.<br />

E.g. “Communication” message if the interlock connector is not fitted.<br />

Actual values<br />

Indication of the actual output values: voltage U, current I and power P.<br />

Set values<br />

Indication of the reference values: voltage U, current I and power P.<br />

TFE display<br />

If the function generator option is enabled and activated, set value -4- changes<br />

to “FGen”. The change in the indication to “FGen” appears as per the function<br />

sequence set.<br />

See DISPLAY 23, 31 function generator Fig. 82, Seite 147.<br />

Table 55 Parameters on the main screen DISPLAY 1, 2<br />

2011-10-18 140 / 298 V00.05b<br />