<strong>Manual</strong> – TopCon TC.GSS<br />

7.2. Analogue interface<br />

Analogue interface<br />

Activation of the analogue interface for remote control<br />

Short description of the analogue interface<br />

The operation of the analogue interface is defined by the pin definition<br />

for the analogue interface X105.<br />

Set values can be specified by applying a reference voltage to the inputs<br />

for U, I, P, R on the analogue interface.<br />

Pin definition of the analogue interface X105<br />

For further information see 10.1.6.6, page 271.<br />

Activation of the analogue interface for remote programming<br />

For further information see chapter 7.2.1, page 120.<br />

Utilisation of the Multi Rack Controller (MRC)<br />

Operation of the master devices in several multi-unit systems to<br />

form a large multi-unit system.<br />

7.2.1. Activation of the analogue interface for remote control<br />

The analogue interface can be activated via all the interfaces in the<br />

device, and also via the analogue interface itself.<br />

Activation of the analogue interface without HMI for remote control<br />

The analogue interface is activated via itself.<br />

Activation is via pin 20 on the digital input on the analogue interface by<br />

means of the following signals:<br />

Rising edge from 0 V to 24 V.<br />

If the ANALAOG_REFERENCE_SELECT signal has already<br />

reached the high level of 24 V on power-up.<br />

For information on the pin definition see Table 147, page 271.<br />

Pay attention to the interface hierarchy.<br />

2011-10-18 120 / 298 V00.05b<br />