<strong>Manual</strong> – TopCon TC.GSS<br />

8. Maintenance<br />

8.1. Maintenance tasks<br />

Maintenance<br />

Maintenance tasks<br />

Determination of the operating hours<br />

The operating hours represent the time during which the supply voltage<br />

is present at the device independent of the operating state.<br />

The number of operating hours is indicated in the TopControl application<br />

on the tab. See chapter 7.4.8.12, Seite 247.<br />

8.1.1. Maintenance of the hardware<br />

8.1.1.1. Fans<br />

In principle the electronics in the TopCon TC.GSS power supply are<br />

maintenance-free.<br />

However, the following components require maintenance depending on<br />

the number of operating hours:<br />

Fans<br />

Electrolytic capacitors.<br />

The TopCon TC.GSS power supplies contain 3 temperature-regulated,<br />

ball bearing mounted fans to cool the electrical and electronic components.<br />

Life-expectancy – fans<br />

Life-expectancy per fan with an average ambient<br />

temperature of 40 ° C<br />

Table 127 Life expectancy of electrical fans.<br />

2011-10-18 CCXLIX V00.05b<br />

8<br />

40,000 operating hours<br />

Use a torch and check at regular, intervals with the device switched on,<br />

whether the fans are rotating.<br />

8.1.1.2. Electrolytic capacitors<br />

TopCon TC.GSS power supplies have electrolytic capacitors in the DC<br />

intermediate circuit.<br />

Life expectancy – capacitors<br />

Life-expectancy of the electrolytic capacitors with an<br />

average ambient temperature of 40 ° C<br />

Table 128 Life expectancy of electrolytic capacitors.<br />

100,000 operating hours