<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

10.2.2. Overview of group error codes and group warning codes<br />

Indication of the reason for the malfunction<br />

10<br />

Flashing<br />

code<br />

Group error TopControl/HMI indication 1)<br />

1 Internal error 0) Internal<br />

2 PDSP error 1) Internal (PDSP)<br />

3 Error due to the output current 2) Output current<br />

4 Error due to the output voltage 3) Output voltage<br />

5 Error in the electrical power supply 4) Supply<br />

6 Temperature error 5) Temperature<br />

7 Communication error 6) Communication<br />

8 Modulator error 7) Internal (Modulator)<br />

9 AD_Overrange_1-error 8) Internal (AD overrange 1)<br />

10 AD_Overrange_2-error 9) Internal (AD overrange 2)<br />

11 AD_Underrange_1-error A) Internal (AD underrange 1)<br />

12 AD_Underrange_2-error B) Internal (AD underrange 2)<br />

13 Login error C) Login<br />

14 Configuration error D) Configuration<br />

15 -- (not used) E) Not def.(group 14)<br />

16 Interlock open, miscellaneous F) Interlock open,<br />

Miscellaneous<br />

1) On the HMI/RCU there is not enough space to output the errors or warnings with as much<br />

detail as in TopControl. I.e. the text may be indicated truncated. The code in front of<br />

the text is however identical in TopControl and HMI/RCU<br />

The above list provides an overview of all existing group errors. Some<br />

of the groups can also occur as warnings via the same group code.<br />

The code prefix [ 0) ...F) ] helps to clearly identify the error<br />

group/warning group. This code appears both in TopControl ("Show<br />

Errordetail"/"Show Warndetail" buttons) and also on the HMI/RCU<br />

(Error/Warning menu).<br />

Overview of detail errors and detail warning codes<br />

The following table lists all detail errors. Some of the detail errors can<br />

also occur as warnings with the same code.<br />

The error or the warning can be identified using the flashing code in<br />

column 1 based on the number of flashes on the front panel LEDs.<br />

The “TopControl/HMI indication” column contains the exact wording in<br />

TopControl (“Show Errordetail”/”Show Warndetail” button). The texts<br />

are truncated on the HMI/RCU for space reasons. The errors can however<br />

be unambiguously identified from the code given first.<br />

2011-10-18 277 / 298 V00.05b