<strong>Manual</strong> – TopCon TC.GSS<br />

Options and system options<br />

Software options<br />

The parameters summarised<br />

Setting<br />

Value range –<br />

TopControl<br />

Value range – HMI<br />

Base function Sine, square, triangle, user-defined, AAP<br />

Amplitude 0...100 %, resolution: 12 bits<br />

Offset<br />

Standard: 0 – 100 %<br />

Bipolar:-100 % – +100 %<br />

Resolution: 12 bits<br />

Resolution: 12 bits<br />

Symmetry 0...100 % (only with triangle and square)<br />

Frequency 0.001 Hz – 1 kHz 0.01 Hz – 320 Hz<br />

Exponential envelope (time<br />

constant)<br />

Rectify negative amplitude Yes/no<br />

Amplitude polarity Unipolar/bipolar<br />

No. of repetitions<br />

of the base function<br />

0.1 ms – 100000 s 10 ms – 320 s<br />

1 – 65535<br />

or continuous<br />

Cannot be changed,<br />

Standard: no<br />

Cannot be changed,<br />

Standard: bipolar<br />

0 – 32000<br />

(0 ≙ continuous)<br />

Table 35 Possible function generator settings with comparison between TopControl and HMI.<br />

Loading and saving function sequences<br />

All the settings can be saved in the non-volatile memory (flash) and<br />

loaded again. It is also possible to set that when the power supply is<br />

started (power-up), a previously saved function sequence is loaded automatically.<br />

Several function sequences can be saved. 64kB of memory<br />

are available for this feature. Without user-defined curve shapes, up to<br />

256 function sequences can be saved. In the case of user-defined<br />

curves (4 bytes per point) the number reduces accordingly.<br />

The function sequences are saved in a sequence number (1...1000)<br />

that can be selected and can be called again using this number. It is also<br />

possible to call the function sequences from the HMI. On saving a<br />

function sequence via TopControl it is also possible to give an arbitrarily<br />

defined name (up to 31 characters) as well as the date and time.<br />

Restrictions and information<br />

The function generator makes it possible to specify complex set value<br />

curves. For the output values on the power supply to also be able to follow<br />

these set value curves, the following points are to be noted:<br />

2011-10-18 84 / 298 V00.05b<br />