Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

10.2.2.6. Error group 5) Temperature<br />

Group error: 5) Temperature<br />

Flashing<br />

code<br />

TopControl/ HMI<br />

indication<br />

6-1 50) Rectifier temp.<br />

too high<br />

6-2 51) IGBT temp.<br />

Description<br />

Heat sink temperature in<br />

the area of the output<br />

rectifier or IGBT power<br />

stage too high<br />

Possible reason<br />

Measure to rectify<br />

10<br />

Flow of inlet or outlet cooling air obstructed<br />

Replace any clogged filters. Create sufficient space<br />

for inlet and outlet air<br />

too high - Ambient temperature too high<br />

- Load current too high (pay attention to temperature derating)<br />

Reduce ambient temperature<br />

Adjust load to the ambient temperature (derating)<br />

6-3 52) TCLIN K1<br />

temperature too<br />

high<br />

6-4 53) TCLIN K2<br />

temperature too<br />

high<br />

6-5 54) TCLIN PCB<br />

temperature too<br />

high<br />

Heat sink temperature<br />

at measuring point K1<br />

or K2 too high<br />

Temperature of the<br />

printed circuit board<br />

too high<br />

-) Cooling is not operating satisfactorily<br />

Check air inlet/outlet?, fans ok?<br />

-) Power loss excessive<br />

Reduce drop voltage<br />

-) NTC K1/K2 /PCB has cable break, other defect<br />

Contact support<br />