<strong>Manual</strong> – TopCon TC.GSS<br />

Operating modes<br />

Setting operating states<br />

4.2.2.2. Setting set values via HMI<br />

For further information on the operation of the HMI see chapter 7.3,<br />

page 131.<br />

The specification of the parameters using the HMI is only fully suitable<br />

for Q1 operation.<br />

For Q4 operation it only possible to specify set values for the current,<br />

voltage and power, but not for the limit values.<br />

1<br />

3<br />

5<br />

Output settings<br />

Voltage<br />

Current<br />

Power limit<br />

internal resistance<br />

*Quit menu*<br />

Fig. 16 Output settings display - HMI window<br />

Procedure for Q1/Q4 operation<br />

Set the required voltage -1-.<br />

Output settings<br />

Voltage<br />

Current<br />

Power limit<br />

internal resistance<br />

*Quit menu*<br />

Set the required set values for current and power -2-.<br />

“+” sign = Q1 operation; “-” sign = Q4 operation<br />

For Q1 operation set the corresponding limit values<br />

for the power -3-.<br />

Start the flow of energy from the AC side to the DC side using<br />

the switch on the HMI panel.<br />

4.2.2.3. Setting set values via the analogue interface X105<br />

For further information on the operation of the device via the analogue interface<br />

X105 see chapter 7.2 , page 120.<br />