04.03.2013 Views

Manual

Manual

Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Manual</strong> – TopCon TC.GSS<br />

Group error: C) Login (continued)<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

13-7 C6) TCLIN<br />

missing<br />

13-8 C7) Master did<br />

not receive all<br />

RFL subframes<br />

from HMI/RCU<br />

13-9 C8) CAN protocol<br />

version is not<br />

identical<br />

13-10 C9) Software<br />

version is not<br />

identical<br />

13-11 CA) Slave CAN<br />

protocol version<br />

is not identical<br />

13-12 CB) HMI/RCU<br />

CAN protocol<br />

version is not<br />

identical<br />

-- 2)<br />

CC) HMI/RCU<br />

did not receive<br />

CFL<br />

Description<br />

Appendix<br />

Error list<br />

The TopCon master is<br />

not finding a TCLIN on<br />

system start<br />

The same CAN protocol<br />

or the same software<br />

is not installed<br />

on all devices<br />

The HMI/RCU version<br />

does not match the<br />

actual firmware<br />

The HMI/RCU has not<br />

received a request to<br />

log into the system<br />

Possible reason<br />

Measure to rectify<br />

10<br />

The TopCon master cannot establish the connection.<br />

Restart: switch on TC.LIN before TC.P<br />

Check CAN cable<br />

The software versions on devices involved must be<br />

identical to the versions on the master device<br />

Contact the manufacturer to obtain compatible versions<br />

A master has not been defined<br />

Ensure that a TopCon master (module ID=0) is<br />

available<br />

There is no voltage at the controller board for the master<br />

(LEDs remain off on switching on)<br />

On repeated occurrence contact the manufacturer<br />

Master device was switched on before the HMI/RCU<br />

was switched on<br />

Always switch on master at the same time or after<br />

all HMI/RCU (maintain 10-second timeout)<br />

Master device was not switched on after the end of the<br />

10s HMI/RCU timeout<br />

Also switch on master within 10s of switching on the<br />

HMI/RCU<br />

Master slave cable or RCU cable not connected<br />

Check cabling<br />

TC.GSS power supplies in generation 3 will only run<br />

with HMI firmware V1.xx.yy. TopCon power supplies in<br />

generation 4 (TopCon Quadro) will only run with HMI<br />

firmware V4.xx.yy or V11.xx.yy<br />

Only operate compatible devices in a multi-unit system.<br />

Subsequent error for a CAN bus error<br />

See above, error 60/61)<br />

2011-10-18 290 / 298 V00.05b