<strong>Manual</strong> – TopCon TC.GSS<br />
TopControl application<br />
Tab – <br />
tab – “Function Block” group (continued)<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
Frequency, text box<br />
Frequency for the base function.<br />
Cannot be applied to user-defined function and with AAP. There the time is<br />
defined individually for each separate point or there is no time dependency.<br />
Value range: 0.001 Hz – 1000 Hz<br />
Symmetry, text box [%]<br />
Ratio between positive signal value and the period, like that for the positive<br />
signal edge for the triangle, or signal pulse for square<br />
Value range: 0 % – 100 %; default 50 %<br />
Rectify Amplitude, check box<br />
To select “Rectify Amplitude” -9- must be selected.<br />
For user-defined and AAP functions this check box cannot<br />
be selected.<br />
(See “Base Function” group -3-).<br />
Selected: Rectification of negative amplitudes (positive values only)<br />
Cleared No rectification.<br />
Bipolar Amplitude, check box<br />
Defines the value range for the base functions:<br />
Sine, square and triangle<br />
Value range (amplitude -4-):<br />
Selected: Function values between - Amplitude and + Amplitude.<br />
Cleared: Function values between 0 and +Amplitude.<br />
Exponential envelope, check box and text box [s]<br />
Activates and deactivates an exponentially decaying amplitude envelope over<br />
the entire length of the function block. The information on the time constant is<br />
given in seconds. Within this time the amplitude falls to 37 %.<br />
The envelope starts after the amplitude has passed the maximum value for<br />
the first time (sine: after ¼ of the first period). In case of user-defined functions,<br />
on the other hand, the envelope starts only after the first period.<br />
The envelope only affects the amplitude, not the offset.<br />
Value range: 0.0001 s – 100000 s, step width: 0.0001 s,<br />
default : 0.0001 s<br />
AAP input filter, list box<br />
Is ready for an entry if in the “Base Function” -3- “AAP” is selected in the list box.<br />
Using the input low pass filter, interference on the signal input (X axis on the<br />
AAP curve) can be filtered out.<br />
Value range: 0.1 Hz – 1600 Hz TP cut-off frequency, default: Off,<br />
Step width: doubling of the previous value<br />
AAP input scale, text box [%]<br />
Is ready for an entry if in the “Base Function” -3- group “APP” is selected in<br />
the list box and “allow manual scaling” is selected.<br />
The curve is compressed on the input side (X axis of the AAP curve) to the<br />
percentage entered.<br />
Value range: 0 % – 100 %, step width 1 %, default: 100 %<br />
Ramp time, text box<br />
For applications see online help using the TopControl button<br />
Value range: 0 – 86400 s; step sequence: 0.001 s; default: 0 s<br />
Table 93 Parameters in the “Function Block” group.<br />