<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

10.2.2.16. Error group F) Miscellaneous<br />

Group error: F) Miscellaneous<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

16-1 F0) Voltage<br />

sensing not<br />

allowed in<br />

series configuration<br />

16-2 F1) Wrong op-<br />

Description<br />

Possible reason<br />

Measure to rectify<br />

It is not allowed to activate the sense functionality on operation in series<br />

Only use sense functionality in single operation or in a parallel<br />

multi-unit system<br />

tion code<br />

An invalid option code has been entered<br />

Enter option code again correctly, if necessary contact the manufacturer<br />

16-3 F2) Interlock As soon as the interlock Interlock circuit has not been wired<br />

circuit is disconnected, (for correct wiring see operating instructions)<br />

the power stage shuts Fit suitable connectors to interface X105 and<br />

down.<br />

X101/X102<br />

Connect interlock circuit differently, e.g. using<br />

relay contacts<br />

16-4 F3) External<br />

PWM shutdown<br />

Shutdown of the power<br />

stage caused by an external<br />

signal<br />

10<br />

Interlock circuit has been opened by external protection<br />

circuit<br />

Check why the protection circuit has tripped<br />

The signal is normally not wired to the output. I.e.<br />

only very heavy EMI could cause this error<br />

Locate source of EMI, e.g. contactors without<br />

free-wheeling diodes<br />

On repeated occurrence contact the<br />

manufacturer<br />

Customer-specific error<br />

16-5 F4) Security<br />

relais open<br />

16-11 FA) Any Rack<br />

system did<br />

not change<br />

to voltage-on<br />

or –off within<br />

specified<br />

timeout<br />

16-12 FB) Any Rack<br />

system has<br />

errors, or<br />

dummy plug<br />

missing<br />

Customer-specific error<br />

16-13 FC) ReGen error Error in an optional ex- See separate documentation on the overall<br />

ternal regeneration unit system<br />

16-14 FD) AC-Switch Error in the external See software documentation V11.09.00<br />

error polarity reverse bridge<br />

(simple variant with contactors)<br />

16-15 FE) AC-Bridge Error in external<br />

See operating instructions for the bipolar<br />

error TopCon bipolar switch<br />

(TopCon option)<br />

switch<br />

16-16 FF) FIFO queue Buffer for actual value Subsequent error for a CAN communication error<br />

for actual synchronisation in multi- [Group error 6) ]<br />

values full unit operation is full See group error 6)<br />

2011-10-18 294 / 298 V00.05b