<strong>Manual</strong> – TopCon TC.GSS<br />

Sense configuration<br />

Single device operation – special aspects<br />

Sense connection<br />

+<br />

X104 S+<br />

S -<br />

1<br />

-<br />

-<br />

2011-10-18 44 / 298 V00.05b<br />

+<br />

X104 S+<br />

S -<br />

Fig. 21 Connection of load with sense function, not switched -1- or<br />

switched -2-.<br />

The sense cables are connected directly across the load. Here it is allowed<br />

to install a switch (contactor) -2- in the load circuit. The maximum<br />

output voltage Uout can be configured via the software. The output voltage<br />

can be limited via the value configured. For further information on<br />

the significance of the parameters see chapter 7.4.8.1 ,page 175.<br />

Output of the sense voltage via the analogue interface X105<br />

With the sense function activated, the analogue sense voltage actual<br />

value can be used for the indication via the analogue interface X105.<br />

For further information on the pin definition of X105 see chapter<br />

10.1.6.6, page 271.<br />