<strong>Manual</strong> – TopCon TC.GSS<br />

10.1.2. Leakage current<br />

Appendix<br />

Technical data<br />

10<br />

The following leakage current events are produced by the correct<br />

function of the mains filter.<br />

Leakage current<br />

condition<br />

“Voltage ON”<br />

without load<br />

“Voltage ON”<br />

with full load<br />

Total<br />

leakage<br />

current<br />

Frequency range<br />

50 Hz ≤ 100 Hz 150 Hz ≤ 1 kHz > 1 kHz<br />

100 mA 1 mA 2 mA 2 mA 3 mA 100 mA<br />

114 mA 5 mA 5 mA 1 mA 6 mA 114 mA<br />

Table 135Leakage current – Measured result on a TC.GSS power supply with 32 kW XXXX<br />

(still needs to be expanded) with no load and with load.<br />

If you want to use an earth leakage trip, use a device with an expanded<br />

frequency range.<br />

Please take note of the varying requirements for protection against fire<br />

and the protection of individuals.<br />

Regatron recommends the usage of an earth leakage circuit breaker<br />

sensitive to AC and DC leakage currents.<br />