<strong>Manual</strong> – TopCon TC.GSS<br />

Analogue interface<br />

Remote programming for current and voltage<br />

7.2.4. Remote programming for current and voltage<br />

If this set value setting is not required, these inputs can be left unconnected<br />

or<br />

connected<br />

to the analoguereference<br />

earth.<br />

Fig. 62 Analogue set value specification using potentiometers -1-.<br />

Analogue set value specification using external sources -2-.<br />

Pin Analogue control Function<br />

2<br />

3<br />

Voltage<br />

set value<br />

Current<br />

set value<br />

10kΩ<br />

10kΩ<br />

Voltage VREF<br />

0…10 V or<br />

0…10 kΩ<br />

1<br />

Current IREF<br />

-10V …0…10 V<br />

or 0…10 kΩ<br />

1<br />

6 +10VDC<br />

2 VREF<br />

3 IREF<br />

1 AGND<br />

Shield earthed<br />

X105<br />

Voltage<br />

set value<br />

Current<br />

set value<br />

Voltage Umax== Unom * [0.. 100%]<br />

where VREF ≙ [0.. 100%]<br />

Current Imax = Imax * [-100% … 0 ...100%]<br />

where IREF ≙ [-100% … 0 ... 100%]<br />

Table 44 Factory pin definition and value range for the manipulated values VREF and IREF.<br />

1 Only positive set values can be specified with a resistor (0 … 10 KΩ).<br />

2011-10-18 123 / 298 V00.05b<br />

=<br />

=<br />

2<br />

7<br />

6 +10VDC<br />

2 VREF<br />

X105<br />

3 IREF<br />

1 AGND<br />

Shield earthed