<strong>Manual</strong> – TopCon TC.GSS<br />

Device states<br />

Single device operation – special aspects<br />

Internal system status and troubleshooting<br />

As a consequence there exist different device states:<br />

State Description<br />

ST_POWERUP<br />

ST_READY<br />

ST_RUN<br />

ST_WARN<br />

Initialisation phase,<br />

CAN login,<br />

all modules asynchronous<br />

All modules ready,<br />

output electrically isolated,<br />

fans off 1<br />

Output live,<br />

controlled to set values,<br />

fans on<br />

As for ST_RUN,<br />

at least one warning flag set<br />

ST_ERROR<br />

Error in at least one module,<br />

output electrically isolated,<br />

fans off 1<br />

ST_STOP Stop state for software update<br />

FATAL_ERROR Internal communication failed<br />

Table 20 Internal system states.<br />

1 Depending on the temperature, the fans may continue to operate at reduced<br />

speed.<br />

The device state is output to the exterior on the following interfaces:<br />

Device and control/LEDs (light emitting diode on the front panel)<br />

Green: POWER<br />

Yellow: STATUS<br />

Red: ERROR<br />

For information on the control console see chapter 4.1, page 31.<br />

Digital outputs<br />

The relay contacts are operated in a corresponding manner and<br />

permit the connection of external status indications.<br />

For further information see chapter 4.3.5.3, page 53.<br />

2011-10-18 51 / 298 V00.05b<br />