<strong>Manual</strong> – TopCon TC.GSS<br />

Error-free state<br />

Installation and commissioning<br />

Switching on and off a TopCon power supply<br />

After you have set the set values, the following occurs in the error-free state:<br />

The output is switched on and regulated to the related set value<br />

defined.<br />

The device is in the state: RUNNING,<br />

One CONTROL LED illuminates depending on the controller that<br />

is providing the limiting.<br />

CV for voltage controller<br />

CC for current controller<br />

CP for power controller<br />

Error state<br />

In the error state a flashing error code is output on the front via the<br />

CONTROL LED.<br />

For further information see chapter 10.2, from Seite 275.<br />

If there is no output voltage at the device, check the interlock circuit using the<br />

related dummy plugs.<br />

For further information see chapter 4.3.3, Seite 48.<br />