10.2.2.2. Error group 1) Internal (PDSP)<br />

Group error: 1) Internal (PDSP)<br />

Flas<br />

hing<br />

code<br />

TopControl/<br />

HMI<br />

indication<br />

2-1 10) PDSP packagechecksum<br />

2-2 11) Wrong<br />

PDSP SW version<br />

Description<br />

System communication<br />

malfunction<br />

Peripheral DSP version<br />

does not match the<br />

MainDSP version<br />

2-3 12) PDSP fault Internal has occurred.<br />

2-4 13) Write queue<br />

overrun<br />

2-5 14) Too many<br />

PDSP packages<br />

2-6 15) SCI checksum<br />

2-7 16) SCI parity<br />

2-8 17) SCI overrun<br />

2-9 18) SCI framing<br />

2-10 19) SCI break<br />

Possible reason<br />

Measure to rectify<br />

Heavy EMI pulse<br />

Earth devices using large area connections<br />

Locate source of EMI,<br />

e.g. contactors without free-wheeling diodes<br />

10<br />

- During a software update the peripheral DSP has not<br />

yet been updated to the latest state<br />

- Latest parameters not loaded after software update<br />

Undertake software update exactly as stated in the<br />

instructions<br />

On repeated occurrence contact the manufacturer<br />

Various RS232 errors - Interference on RS232 cable<br />

Earth devices using large area connections<br />

Possibly use shorter cable<br />

Possibly use shielded cable<br />

Avoid earth loops, electrically isolate RS232<br />

Locate source of EMI,<br />

e.g. contactors without free-wheeling diodes<br />

- Wrong RS232 timing set (baud rate, stop bit, parity bit,<br />

...)<br />

For correct values see operating instructions<br />

- Level switching on RS232 after switching on or off a<br />

PC/laptop<br />

(Error 18) )<br />

Connect RS232 cable only after starting the<br />

PC/laptop or disconnect prior to switch off<br />

Update the peripheral DSP to V0.11<br />

- Incorrect inactive RS232 level on host side as long as<br />

interface is not opened<br />

(Error 18) )<br />

Update the peripheral DSP to V0.11<br />

Start TopControl and leave to run to open the<br />

interface. The error cannot be acknowledged<br />