<strong>Manual</strong> – TopCon TC.GSS<br />

Single device operation – special aspects<br />

CAN communication (X101/102)<br />

4.3.2. CAN communication (X101/102)<br />

TopCon power supplies that are operated in a multi-unit system require<br />

system-internal communication via the related interfaces X101/X102.<br />

The tasks of the individual TopCon power supplies and their peripheral<br />

modules, e.g. RCUs and series controllers are controlled via the CAN<br />

communication. At the same time the CAN communication is used for<br />

communication between the system master and the slaves assigned.<br />

The interfaces X101 and X102 have the following tasks:<br />

CAN interface, for the communication<br />

Interlock connection<br />

The related interface must always be “terminated”, i.e. fitted with the related<br />

dummy plugs or a bus connection.<br />

4.3.2.1. Assignment of interface and dummy plug<br />

Dummy plug<br />

1<br />

2<br />

3<br />

X105<br />

Interlock CTR 4<br />

1<br />

X101<br />

CAN TERM<br />

Interlock CTR 4<br />

2011-10-18 46 / 298 V00.05b<br />

2<br />

4<br />

X101<br />

CAN TERM<br />

CTR 4<br />

Fig. 24 Schematic illustration of the D-Sub dummy plugs used with their<br />

labelling.<br />

Interlock connector, D-Sub, 25-pin (dummy plug)<br />

Label: “X105; Interlock CTR 4”<br />

Is connected on the rear side of all devices to interface X105.<br />

Interlock or CAN-Term, D-Sub, 9-pin (dummy plug)<br />

Label: “X101; CAN TERM; Interlock CTR 4“<br />

Is connected to interface X101 on the rear side of the device at the start of the<br />

CAN multi-unit system.<br />

CAN-Term, D-Sub, 9-pin (dummy plug)<br />

Label: “X101; CAN TERM;”<br />

Is connected to interface X102 on the rear side of the device at the end of the<br />

CAN multi-unit system.<br />

Table 17 Dummy plugs and their labelling.<br />

Only one CAN-Term is allowed to be connected to a single device.<br />

Independent of whether X101 or X102 is used.<br />