04.03.2013 Views

Manual

Manual

Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Manual</strong> – TopCon TC.GSS<br />

TopControl application<br />

Tab – <br />

Reference values group – “Ref.values”<br />

siCTR_Ref<br />

ImoduleAfterLimits<br />

siCTR_RefIsystem<br />

siCTR_Ref<br />

PmoduleAfterLimits<br />

siCTR_RefPsystem<br />

siCTR_Ref<br />

UmoduleAfterLimits<br />

siCTR_RefUsystem<br />

Module current reference value for the module controller<br />

In single device operation: ≙ RefIsystem after ramp and<br />

internal resistance correction<br />

Value range: 0 – 4000; (4000 ≙ Maximum current)<br />

Device role: Valid for master<br />

System current reference value (set value)<br />

Value range: 0 – 4000;<br />

Single device operation: 4000 ≙ Nominal device current<br />

Multi-unit operation: 4000 ≙ Nominal system current<br />

Reference value via analogue, RS-232, HMI/RCU interface<br />

Device role: Valid for master<br />

Voltage reference value for the module controller<br />

Single device operation: ≙ RefPsystem after ramp and<br />

internal resistance correction<br />

Value range: 0 – 4000; (4000 ≙ Maximum<br />

current)<br />

Device role: Valid for master<br />

Voltage reference value for the module controller<br />

Value range: 0 – 4000;<br />

Single device operation: 4000 ≙ Nominal device power<br />

Multi-unit operation: 4000 ≙ Nominal system power<br />

Reference value via analogue, RS-232, HMI/RCU interface<br />

Device role: Valid for master<br />

Module voltage reference value for the module controller<br />

Single device operation: ≙ RefUsystem after ramp and<br />

internal resistance correction<br />

Value range: 0 – 4000;<br />

(4000 ≙ Maximum voltage)<br />

Device role: Valid for master<br />

System voltage reference value (set value)<br />

Value range: 0 – 4000;<br />

Single device operation: 4000 ≙ Nominal device voltage<br />

Multi-unit operation: 4000 ≙ System nominal voltage<br />

Reference value Via analogue, RS-232,<br />

HMI/RCU interface<br />

Device role: Valid for master<br />

Table 107 Description of the reference values that are allocated to the “Ref.values” group<br />

(set values).<br />

2011-10-18 211 / 298 V00.05b<br />