<strong>Manual</strong> – TopCon TC.GSS<br />

Installation of the software<br />

Procedure on establishing communication<br />

7.4.3.2. Start/communication with the TopCon power supply<br />

Procedure on establishing communication<br />

Switch on the power supply.<br />

Start the TopControl application.<br />

The software searches for the COM ports from port 0..10.<br />

A connection is made automatically to the first TopCon power<br />

supply connected via the serial interface.<br />

If the TopCon power supply is not detected by the TopControl<br />

application, the following message window appears.<br />

Fig. 88 Message window if TopControl does not detect the TC.GSS power<br />

supply.<br />

The software is run in the Offline mode as soon as you accept<br />

the message using the button.<br />

Check the RS-232 connections!<br />

Is the interface perhaps in use by another program or another instance<br />

of TopControl?<br />

If the virtual COM port > 10, you can connect a power supply to<br />

the TopControl application using the following console command:<br />

„C:\Program Files\Regatron\TopControl\TopControl.exe<br />

/COMStart=5 /COMEnd=5'<br />

Where COMStart= start of search and COMEnd= end of search<br />

If the connection problem persists, please contact Regatron support.<br />

If the communication between the TopControl application and the Top-<br />

Con power supply fails, the connection can be re-established manually.<br />