<strong>Manual</strong> – TopCon TC.GSS<br />

Operating modes<br />

Feeding and regenerative operation<br />

The following cases are defined by the properties of the load connected and<br />

the operating mode:<br />

Actual value ≤ reference value:<br />

Depending on which control difference is smaller the following<br />

occurs:<br />

Voltage control cv with a ULoad limit at UREF or<br />

current control cc with an ILoad limit at IREF or<br />

power control cp with a PLoad limit at PREF<br />

Actual value > reference value:<br />

The control does not allow the reference value to be exceeded.<br />

For example, the voltage control attempts to maintain<br />

ULoad =UREF. During this process the load current ILoad can also<br />

be negative until the current limit ILimitQ4=-Imax or the power limit<br />

PLimitQ4=-Pmax is reached. Change from Q1 to Q4 operation.<br />

Q4 operation: example case for load voltage UL with reactive<br />

loads:<br />

At IL = ILimitQ4, the current control starts to limit, during this process UL increases.<br />

If UL ≤ UNom the current control cc remains with ILimitQ4 as the limit.<br />

If UL >UNom voltage control cv with the device safety<br />

limit Umax =1.1*UNom.<br />

If Umax is reached, the device switches off for safety reasons.<br />

2011-10-18 37 / 298 V00.05b<br />