<strong>Manual</strong> – TopCon TC.GSS<br />

CAUTION<br />

TopControl application<br />

Tab – <br />

tab – parameters (continued)<br />

4<br />

5<br />

I 2 t, with following text boxes<br />

For explanation and example calculation see “Example I 2 t parameter ,<br />

Seite 226<br />

Current inom Nominal value for the load connected<br />

Error limit Threshold that causes an overcurrent error.<br />

Value range is device-dependent. (time value required)<br />

Warn limit Threshold that causes an overcurrent warning.<br />

Value range is device-dependent. (time value required)<br />

Store settings, button<br />

Settings made on the tab are permanently saved. The actual<br />

parameter set is saved from the RAM to the flash PROM in the TC.GSS power<br />

supply.<br />

Table 117 Error and warning thresholds on the tab.<br />

7.4.8.7. Tab – <br />

User level: from Power User<br />

Any adjustments to the measured value acquisition on the inputs and<br />

outputs necessary during the test and setup phase for the TopCon GSS<br />

power supply can be made using the parameters on the <br />

tab.<br />

For further information on analogue remote programming, see chapter<br />

7.2.4, page 123Seite 123.<br />

Damage possible due to decalibration!<br />

Changes to the parameters can cause damage to the load connected:<br />

The control circuit may overshoot, which will involve current<br />

and voltage spikes that can irreparably damage the semiconductors.<br />

Damage to a load connected due to excessively high<br />

voltage, current or power steps.<br />

Incorrect or imprecise display is possible.<br />

Avoidance:<br />

Before you change parameters, make sure a calibration is really<br />

necessary.<br />

Contact support before you make changes to parameters.<br />

Check your procedure for the calibration again before you<br />

save modified parameters on the TC.GSS power supply.<br />

2011-10-18 228 / 298 V00.05b<br />

7