<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

10.2.2.9. Error group 8) Internal (AD overrange 1)<br />

Group error: 8) Internal (AD overrange 1)<br />

Flash<br />

ing<br />

code<br />

TopControl/HMI<br />

indication<br />

9-5 84) Output<br />

voltage overrange<br />

9-6 85) Output<br />

current<br />

overrange<br />

9-7 86) Sense voltage<br />

overrange<br />

9-8 87) System<br />

voltage overrange<br />

9-9 88) System<br />

current overrange<br />

Description<br />

AD-converter for the<br />

output voltage measurement<br />

at upper limit<br />

AD-converter for the<br />

output current measurement<br />

at upper limit<br />

AD-converter for the<br />

sense voltage measurement<br />

at upper limit<br />

AD-converter for the<br />

RMB voltage measurement<br />

at upper limit<br />

AD-converter for the<br />

RMB current measurement<br />

at upper limit<br />

Possible reason<br />

Measure to rectify<br />

Overvoltage<br />

See above, error 30) *)<br />

Overcurrent<br />

See above, error 21) *)<br />

Overvoltage<br />

See above, error 30) *)<br />

Overvoltage<br />

See above, error 30) *)<br />

Overcurrent<br />

See above, error 21) *)<br />

10.2.2.10. Error group 9) Internal (AD overrange 2)<br />

Group error: 9) Internal (AD overrange 2)<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

10-1 90) +5V<br />

overrange<br />

10-2 91) +15V<br />

overrange<br />

10-3 92) -15V<br />

overrange<br />

10-4 93) +24V<br />

overrange<br />

10-5 94) IGBT<br />

temperature<br />

overrange<br />

10-6<br />

95) Rectifier temperature<br />

overrange<br />

Description<br />

AD-converter for the<br />

internal supply monitoring<br />

at upper limit<br />

AD-converter for the<br />

IGBT temperature sensor<br />

at upper limit<br />

AD-converter for the<br />

rectifier temperature<br />

sensor at upper limit<br />

Possible reason<br />

Measure to rectify<br />

Internal supply voltages too high<br />

See above, related supply error (group error 4)<br />

Heat sink temperature lower than approx. 0°C<br />

Operate device at higher ambient temperature<br />

Temperature sensor not connected or faulty<br />

Contact manufacturer<br />

Temperature sensor not connected or faulty<br />

Contact manufacturer<br />